Power from 94 kVA to 700 kVA | 1500 rpm. | 50 Hz

Table:LDE V Series 50 Hz (click to enlarge)

Catalogue:4-Catalogue_Genset_LDE-V.pdf
LDE V Series
Series LDE V50 Hz - 400/230 V 1500 rpmOverall dimensions and weights - GenSet without housingOverall dimensions and weights - GenSet with housing (72±3 dBA - 7m)
TypeEngineCylindersVolume (cm 3)Fuel consumption
75% load    - g/kWh
Standby power  (kVA)Prime power (kVA)LxWxH (mm)Weight (kg)LxWxH (mm)Weight (kg)
LDE 94 V TAD 530 GE 4 4760 218 94 85 2500x1100x1530 1300 2500x1100x1860 1600
LDE 110 V TAD 531 GE 4 4760 217 110 100 2500x1100x1530 1350 2500x1100x1860 1650
LDE 143 V TAD 532 GE 4 4760 209 142 130 2500x1100x1530 1390 2500x1100x1860 1690
LDE 167 V TAD 531 GE 6 7150 215 167 152 2750x1200x1530 1650 2750x1300x1860 2000
LDE 205 V TAD 532 GE 6 7150 212 205 186 2750x1200x1530 1750 2750x1300x1860 2100
LDE 226 V TAD 533 GE 6 7150 215 226 205 2950x1200x1750 1850 2750x1300x1860 2200
LDE 275 V TAD 534 GE 6 7150 217 275 250 3300x1400x1850 2000 2950x1300x1860 2550
LDE 305 V TAD 940 GE 6 9360 197 305 277 3300x1400x1850 2550 3300x1400x2300 3100
LDE 346 V TAD 1341 GE 6 12780 194 346 315 3300x1400x1850 3150 3300x1400x2300 3700
LDE 358 V TAD 941 GE 6 9360 200 358 326 3300x1400x1850 2550 3300x1400x2300 3100
LDE 387 V TAD 1342 GE 6 12780 193 387 352 3300x1400x1850 3150 3300x1400x2300 3730
LDE 414 V TAD 1343 GE 6 12780 192 414 378 3300x1400x1850 3200 3300x1400x2300 3750
LDE 452 V TAD 1344 GE 6 12780 198 452 412 3300x1400x1850 3500 3300x1400x2300 4050
LDE 477 V TAD 1345 GE 6 12780 197 477 451 3300x1400x1850 3600 3300x1400x2300 4150
LDE 506 V TAD 1640 GE 6 16120 194 506 462 3600x1600x2150 3790 3600x1600x2450 4230
LDE 559 V TAD 1641 GE 6 16120 195 559 509 3600x1600x2150 3850 3600x1600x2450 4300
LDE 630 V TAD 1642 GE 6 16120 195 630 570 3600x1600x2150 3950 3600x1600x2450 4390
LDE 700 V TWD 1643 GE 6 16120 196 700 630 4000x1900x2150 4160 4000x1900x2450 4900

genset for island operation, standby and parallel operation with the network and / or other genset. standard equipment of the generating sets: engine cooling system, starter, alternator and exhaust silencer, alternator with automatic voltage regulator (avr), baseframe with fuel tank and the collecting vessel, basic wiring, batteries, coolant and lubricating oil.

Volvo Engines

Diesel engines, 4-stroke, direct injection, charging through the turbine and / or intercooled, suitable for continuous operation or standby operation.

Benefits of Volvo engines are reliability, power and economy. Well-balanced engines to ensure a smooth operation without vibration and low noise level. To maintain a controlled temperature in the cylinders and combustion chambers the engine is equipped with piston cooling. It is also equipped with replaceable cylinder linings and valve seats to provide maximum durability and extended engine life. High fuel injection technology and filling with small internal losses contributes to excellent combustion and low fuel consumption, allowing low emissions, to ease of use of the engine contribute also easy accessible services and maintenance.

Alternators

the alternators are synchronous, three-phase, brushless, self-regulated, self-excited, self-ventilated and 4 pole. insulation class h (temperature rise according to class f or b on request). tropical impregnation for salty-humid environment is possible on request. automatic voltage regulation. protection class ip21 or ip23 (other class on request).

Base Frame

steel construction - monobloc. anti-vibration mounting to eliminate the vibration. powder coated with primer and  cover color. the base frame is designed to enable simple lifting and moving the generating set.

Fuel Tank

the fuel tank is mounted on the inside of the base frame. under the fuel tank, a collecting vessel is mounted, which prevents outpouring of any liquid from the generating set into the environment. equiped with all necessary connectors and sensors. standard autonomy of the tank is 8-10 hours at 75% load. additional freestanding double wall tanks and automation for pumping fuel on demand.

Control Panels

manual – includes a manual control unit (push button / key start type), main circuit breaker, differential protection and all auxiliary controls and alarms.

automatic – includes an automatic control unit that starts the genset in case of mains failure (it can be started manually too), main circuit breaker, differential protection and all auxiliary controls and alarms, button for emergency stop, changeover genset / mains (ats) on request.